LF80C ZeniD RFID Reader 7 Operation
Product Manual 7.3 Operation of SECS Protocol
Host requests reader attributes with S18F1
Host to Reader: S18F1
15:19:31 Outgoing: ENQ ( 05 )
15:19:31 Incoming: EOT ( 04 )
15:19:31 Outgoing: Length Byte ( 5A )
15:19:31 Outgoing: Header ( 01 FF 92 01 80 01 00 00 00 03 )
15:19:31 Outgoing: Data (
01 02
41 04 31 32 33 34
01 04
41 0D 43 6F 6E 66 69 67 75 72 61 74 69 6F 6E
41 0B 41 6C 61 72 6D 53 74 61 74 75 73
41 11 4F 70 65 72 61 74 69 6F 6E 61 6C 53 74 61 74 75 73
41 15 53 6F 66 74 77 61 72 65 52 65 76 69 73 69 6F 6E 4C 65 76
65 6C )
15:19:31 Outgoing: Checksum ( CD 02 )
15:19:31 Incoming: ACK ( 06 )
Reader to Host: S18F2
15:19:31 Incoming: ENQ ( 05 )
15:19:31 Outgoing: EOT ( 04 )
15:19:31 Incoming: Length Byte ( 44 )
15:19:31 Incoming: Header ( 81 FF 12 02 80 01 00 00 00 03 )
15:19:31 Incoming: Data
01 04
41 04 31 32 33 34 TARGETID "1234"
41 02 4E 4F SSACK "NO"
01 04
41 02 30 31 Configuration "01"
41 01 30 Alarmstatus "0"
41 04 49 44 4C 45' OperationalStatus "IDLE"
41 06 56 31 2E 30 2E 30 SoftwareRevision Level
01 04 STATUS <L4>
41 02 4E 45 PMInformation "NE"
41 01 30 Alarmstatus "0"
41 04 49 44 4C 45 OperationalStatus "IDLE"
41 04 49 44 4C 45 HeadStatus "IDLE"
15:19:31 Incoming: Checksum ( 0C 29 )
15:19:31 Outgoing: ACK ( 06 )
The host requests all fundamental CIDRW attributes defined in ATTRID.
The reader answers with the actual attribute values.