EasyManua.ls Logo

Brooks LF80C - Page 144

Brooks LF80C
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Brooks Automation
132 278580 Revision A
7 Operation LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol Product Manual
Host writes new reader attributes with S18F3
Host to Reader: S18F3
17:11:07 Outgoing: ENQ ( 05 )
17:11:07 Incoming: EOT ( 04 )
17:11:07 Outgoing: Length Byte ( 77 )
17:11:07 Outgoing: Header ( 01 FF 92 03 80 01 00 00 00 04 )
17:11:07 Outgoing: Data
01 02
41 04 31 32 33 34
01 04
01 02 Configuration "01"
41 0D 43 6F 6E 66 69 67 75 72 61 74 69 6F 6E
41 02 30 31
01 02 Alarmstatus "0"
41 0B 41 6C 61 72 6D 53 74 61 74 75 73
41 01 31
01 02 OperationalStatus "IDLE"
41 11 4F 70 65 72 61 74 69 6F 6E 61 6C 53 74 61 74 75 73
41 04 4D 41 4E 54
01 02 SoftwareRevisionLevel "V1.0.0"
41 15 53 6F 66 74 77 61 72 65 52 65 76 69 73 69 6F 6E 4C 65
76 65 6C
41 06 56 31 2E 30 2E 30
17:11:07 Outgoing: Checksum ( F2 02 )
17:11:07 Incoming: ACK ( 06 )
Reader to Host: S18F4
17:11:07 Incoming: ENQ ( 05 )
17:11:07 Outgoing: EOT ( 04 )
17:11:07 Incoming: Length Byte ( 2D )
17:11:07 Incoming: Header ( 81 FF 12 04 80 01 00 00 00 04 )
17:11:07 Incoming: Data
01 03
41 04 31 32 33 34 TARGETID "1234"
41 02 4E 4F SSACK "NO"
01 01
01 04 STATUS <L4>
41 02 4E 45 PMInformation "NE"
41 01 31 Alarmstatus "1"
41 04 4D 41 4E 54 OperationalStatus "MANT"
41 04 4E 4F 4F 50 HeadStatus "NOOP"
17:11:07 Incoming: Checksum ( 08 54 )
17:11:07 Outgoing: ACK ( 06 )
The host writes all fundamental CIDRW attributes defined in ATTRID.
The reader answers with the actual attribute values.

Table of Contents