Brooks Automation
134 278580 Revision A
7 Operation LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol Product Manual
Host writes data on page 10 with S18F7
Host to Reader: S18F7
13:14:15 Outgoing: ENQ ( 05 )
13:14:15 Incoming: EOT ( 04 )
13:14:15 Outgoing: Length Byte ( 24 )
13:14:15 Outgoing: Header ( 01 FF 92 07 80 01 00 00 00 18 )
13:14:15 Outgoing: Data
01 04
41 04 31 32 33 34 TARGETID "1234"
41 02 30 41 DATASEG "0A"
A9 02 00 08 DATALENGTH 0x08
41 08 41 42 43 44 45 46 47 48 DATA "ABCDEFGH"
13:14:15 Outgoing: Checksum ( 1A 02 )
13:14:15 Incoming: ACK ( 06 )
Reader to Host: S18F8
13:14:16 Incoming: ENQ ( 05 )
13:14:16 Outgoing: EOT ( 04 )
13:14:16 Incoming: Length Byte ( 2D )
13:14:16 Incoming: Header ( 81 FF 12 08 80 01 00 00 00 18 )
13:14:16 Incoming: Data
01 03
41 04 31 32 33 34 TARGETID "1234"
41 02 4E 4F SSACK "NO"
01 01
01 04 STATUS <L4>
41 02 4E 45 PMInformation "NE"
41 01 30 Alarmstatus "0"
41 04 49 44 4C 45 OperationalStatus "IDLE"
41 04 49 44 4C 45 HeadStatus "IDLE"
13:14:16 Incoming: Checksum ( 08 3B )
13:14:16 Outgoing: ACK ( 06 )
The host writes the ASCII string "ABCDEFGH" to page 10. The reader
confirms the write command with SSACK "NO" in the S18F8 message.