EasyManua.ls Logo

Brooks LF80C - Page 88

Brooks LF80C
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Brooks Automation
76 278580 Revision A
7 Operation LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol Product Manual
Data item examples
Message set The SECS-II message set used by the LDN reader consists of six different
stream types.
Stream 1: (Equipment status)
S1F1 and S1F2 Are you there request
S1F15 and S1F16 Request offline
S1F17 and S1F18 Request online
Stream 2: (Equipment control)
S
S2F13 and S2F14 Request parameter
S2F15 and S2F16 Set parameter
S2F19 and S2F20 Reset send
Stream 3: (Material status)
S3F5 and S3F6 Cassette found send
S3F7 and S3F8 Cassette lost send
S3F11 and S3F12 Read MID at I/O port
S3F13 and S3F14 Return read MID
S3F65 and S3F66 Write MID at I/O port
S3F67 and S3F68 Return write success
S3F73 and S3F74 Lock MID at I/O port
S3F75 and S3F76 Return lock success
Meaning Format Length
1-byte integer 65 01 xx
4-byte integer 71 04 MSB ... ... LSB
ASCII 41 06 1st
chr
2nd
chr
3rd
chr
4th
chr
5th
chr
6th
chr
Zero-length xx 00
List data item 01 03 1st element 2nd element 3rd element