4. Maintenance and Repair VX TopCooler
TopCooler Poppet Open/Close Sensor
Adjustment
Part Number: 606325 Rev. A
TopCooler Poppet Open/Close Sensor Adjustment
ThepoppetisthemoveablelidforthecoolchamberintheTopCooler.Adjustingtheopen/close
sensorsensurespropertravelofthepoppet.
RequiredTools
l
Acomputerrunningaterminalemulatororadumbterminal
l
Small,straight-slotscrewdriver
AdjustmentStrategy
RemoveallmaterialfromtheTopCoolerPoppetandtheCoolTraybeforeproceeding.Keephands
clearoftheTopCoolerPoppetandCoolTrayatalltimes.
Lockout / Tagout
Workingwithenergizedequipmentmaycausesuddenmovementorelectricalshockand
mayresultindeathorseriousinjury.
l
Allenergymustberemovedfromtheequipmentperthefacility’s
Lockout/Tagoutprocedurebeforeservicing.
l
Iflocalproceduresarenotavailable,followtheprocedureforLockout/Tagoutin
OSHA Standard 29CFR 1910.147.
42
Copyright © 2023, Brooks Automation, Inc.