EasyManua.ls Logo

Brother MFC-J6935DW - 4400 Head Driver IC Detects Abnormal Temperature During Operation or Stand-By; Head Flat Cable Detected to be Not Correctly Inserted

Brother MFC-J6935DW
402 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Confidential
2-38
Error Code 4300
Head thermistor defective
- Head thermistor detects -20 degree-C or less, or 80 degree-C or more when power
is ON.
Error Code 4400
Head driver IC detects abnormal temperature during operation or stand-by.
Error Code 4600
Purge count or flushing count overflown.
Error Code 4800
Head flat cable detected to be not correctly inserted.
Step Cause Solution
1 Carriage flat cable connection
failure
Reconnect the carriage flat cable.
2 Head thermistor defective Replace the head/carriage unit.
3 Main PCB defective Replace the main PCB.
Step Cause Solution
1 Carriage flat cable connection
failure
Reconnect the carriage flat cable.
2 Head property information not
input
Input the head property information (refer to
Chapter 5, Section 1.3.24 "Updating of Head
Property Information and Backup/Restoration of
Head Calibration Data (Maintenance mode
68)")
3 Head thermistor defective
Head defective
Replace the head/carriage unit.
4 Main PCB defective Replace the main PCB.
Step Cause Solution
1 Ink absorber box or flushing
box full.
Replace ink absorber box or flushing box,
resetting purge counter or flushing counter.
2 Main PCB defective Replace the main PCB.
Step Cause Solution
1 Carriage flat cable connection
failure
Reconnect the carriage flat cable.
2
Head flat cable connection
failure
Reconnect the head flat cable.
3 Carriage PCB defective Replace the carriage PCB ASSY.
4 Head defective Replace the head/carriage unit.
5 Main PCB defective Replace the main PCB.

Table of Contents

Other manuals for Brother MFC-J6935DW

Related product manuals