10 Removal of Needle holder shaft A
1. Remove the spring .
2. Remove the screw 1, and then remove the plate 1 from the needle bar
supporter assy.
3. Remove the screw 2, and then pull the shaft 2, and then remove the
needle holder shaft A 3 from the needle bar supporter assy.
1 1
3
S07
2 2
S07
11 Removal of PF switch assy.
1. Remove the screw 1, and then remove the presser switch holder 1 from
the base holder assy.
2. Remove the PF switch assy. 2 from the presser switch holder 1.
1 1
2
1
12 Removal of Presser foot lifter
1. Remove the retaining ring E4, and then remove the presser foot lifter 1.