EasyManua.ls Logo

BRP Johnson J25R4SUR - Inspection

BRP Johnson J25R4SUR
265 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
77
ELECTRICAL
ELECTRIC STARTER SYSTEM
4
Inspection
Ignition Switch (Remote Models)
Disconnect the ignition switch from remote control
wiring harness.
Check continuity between switch terminals at the
key positions shown:
OO : Continuity
If out of specification, replace the ignition switch.
Starter Button (Tiller Models)
Disconnect the starter button lead wire.
Check continuity between the wiring leads under
the conditions shown:
If out of specification, replace the starter button.
Neutral Switch
Disconnect neutral switch lead wire.
Check continuity between lead wires while operat-
ing the shift lever of remote control.
If out of specification:
Check switch position adjustment.
Replace neutral switch.
IMPORTANT: After installing neutral switch,
check for proper function.
Starter Motor Relay
Remove CDI unit.
Pull out relay and relay holder from electric parts
holder, then remove relay holder from starter
Key
Position
Switch Terminals
MMB
A
S
C
OFF
OO
ON O O
START OOO
PUSH O O O
Tester probe connection
Continuity
Probe Other Probe
Starter
button
not
depressed
White/Red Brown
No
Starter
button
depressed
Yes
1. Neutral switch 005566
Shift position Continuity
Neutral Yes
Forward No
Reverse No
1. CDI unit 005567
1
1

Table of Contents

Related product manuals