Cross Reference Table between Ultrafeeder and Smart Matrix Feeder Parameters
SMART MATRIX FEEDER 3.5
(**) The PK OUT TIME and PK OUT ALARM parameters operate like the TIME ALARM and TENSION
ERROR parameters, but they allow stopping the machine in case of sudden tension variation (due, for
instance, to a bobbin lock) in order to prevent possible needle breakages.
(***) The PK IN TIME and PK IN ALARM parameters allow stopping the machine, thus avoiding yarn
breakages in case of abnormal increase of Ultrafeeder motor torque, due to irregular yarn unwinding (for
instance in case of a sudden pull).
[FLAT KNIT application]
ULTRAFEEDER parameters
SMART MATRIX FEEDER
parameters
Possible values Window
Level
ADVANCED
PROGR. Parameter
[STYLE EDIT] Menu
P1.1
P1.2
P1.3
P1.4
WORK TENSION
TENSION ERROR
TIME ALARM
INC-DEC TENSION
WORK TENSION A
TENSION ERROR
TIME ALARM
--
[0.2 – 99.5 gr]
[0.1 – 99.5 gr, AUTO]
[0.1 – 25 sec., OFF, AUTO]
--
STD
ADV
ADV
--
P2.1
P2.2
P2.3
EXIT TENSION
RELAX YARN
RELAX SPEED
WORK TENS B
--
--
[0.2 – 99.5 gr , OFF]
--
--
STD
--
--
P3.1
P3.2
P3.3
P3.4
OFFSET AUTO
MOTOR CALIBRA
ACCESS CODE
FEEDER CODE
--
--
--
--
--
--
--
--
--
--
--
--
P4.1
P4.2
P4.3
P4.4
P4.4
P4.6
LANGUAGE
APPLICATION
YARN TYPE
I-DEC NO
STOP NO
MODE
Menu [SERVICE-LANGUAGE]
APPLICATION
YARN TYPE
INC/DEC INPUT
STOP OUTPUT
--
[ITALIAN, ENGLISH, ETC]
Application name
[ALL YARN, ELASTIC]
[NO, NC]
[NO, NC]
--
ADV
ADV
ADV
ADV
--
--
--
--
--
P4.5
STANDARD, ADVANCED
--
--
--
UNICO
EDITOR
EDITOR LOCK
RECOVERY %
--
UNICO
[STANDARD, ADVANCED]
[ACTIVATED, DEACTIVATED]
[0 - 100]
--
[AUTOMODE, OFF]
STD
STD
STD
--
ADV
For detailed information about errors and possible solutions, please refer to the Ultrafeeder manual