EasyManua.ls Logo

btsr SMART WARP - B2 - P_FAST - Configuration of Detection Parameters with Fast Ext Input Active

btsr SMART WARP
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
- 3.20 - SMART WARP
P_FAST - Configuration of Detection Parameters with Fast Ext Input Active
SETUP
!
!!
!
P_FAST
This function allows you to configure the sensor detection parameters during the
normal machine operation at high speed (rating speed).The values indicated on
the screens below represent the default values of the individual parameters.
To increase the value of the various parameters, press
To decrease the value of the various parameters, press
For the meaning of each parameter, please refer to the paragraph “Settings that
affect the sensor detection features”.
to activate the function and to select, in sequence, the following parameters.
Delay Control
Allowed values: [100 ms ÷ 20,000 ms]
Broke (tolerance prior to signal the broken yarn condition)
Allowed values: [0010 ms ÷ 2 s] (*)
Uncut (tolerance prior to signal the uncut yarn condition)
Allowed values: [0010 ms ÷ 2 s] (*)
Sensitivity
Allowed values: [1 ÷ 10]
Delay (reaction time)
Allowed values: [5 ms ÷ 1,000 ms]
Start Frequency
Allowed values: [001 ÷ 010]
Stop Frequency
Allowed values: [001 ÷ 010]
to return to SETUP menu.
(*)This parameter can be de-activated (OFF) pressing

Table of Contents

Related product manuals