Logamatic EMS – 6 720 801 386 2011/05
35
Operation with the user menu
5
3. If desired: hold the button pressed down and turn the rotary selector to change this switching
point to a switch-on or switch-off point.
4. Repeat steps 1 to 3 to change other switching points.
5. Press when you have finished making entries.
6. Hold the button pressed down and turn the rotary selector to save the changed program as
User defined 1 or User defined 2.
The selected program, user defined1 or user defined2, is used from now on for that heating
circuit.
7. Select do not save to cancel.
5.6.4 Entering a switching point
You can use enter switch point to add additional switching points for a heating phase or energy
saving phase (day/night mode) or create a new switching program. You can enter switching points
separately for each day. The minimum time between switching points is 10 min (period for which the
circuit is switched on or off).
1. Turn the rotary selector to select the day of the week.
2. Hold the button pressed down and turn the rotary selector to change the time for this
switching point.
The switching point will flash on the graph until it has been entered completely.
3. Hold the button pressed down and turn the rotary selector to specify a switch-on or switch-
off point.
Once the switching point has been entered completely, all the values flash for three seconds. The
switch point can still be changed during this time. After that the switching point is saved.
4. Repeat steps 1 to 3 to enter other switching points.
5. Turn the rotary selector to switch between the days.
6. Press when you have finished making entries.
If you have changed the program and then do not press any button for five minutes, the
system assumes you have finished making entries and goes on to the next step.
If you want to set switching points for a block of days (Mo-Th, Mo-Fr, Mo-Su, Sa-Su),
select select programme\new programme.
For each start point ([1], day mode), you also need to enter a stop point
([2], night mode) so that the heating will switch back to night mode again.
The maximum number of switch points is 42 per heating circuit.