Logamatic EMS – 6 720 801 386 2011/05
29
Operation with the user menu
5
5.4 Setting standard display
This menu item can be used to select the default value to be displayed in the upper row of the display
screen (permanent display).
1. Open the user menu.
2. Select standard display. You can choose from the following standard displays:
Date + time (basic setting)
outside temperature (recorded outside temperature)
boiler temperature (recorded boiler water temperature, flow temperature)
DHW temperature (in DHW water cylinder)
collector temperature (with solar thermal systems only)
5.5 Selecting the operating mode
5.5.1 Operating modes for RC35 heating circuits
For the RC35 heating circuits the operating mode can be set directly through pressing the
respective button (e.g ). For other heating circuits, use this menu item. If the heating circuit is
equipped with a remote control unit (e.g. RC2x/RC20/RF), you can also use the operating mode
keys on the remote control.
1. Open the user menu.
2. Select operation modes.
3. If your heating system is equipped with more than one heating circuit (Æ page 26): select the
required heating circuit and confirm.
4. Set the operating mode for the selected heating circuit:
Automatic (switching program)
Continuous heating (manual day mode)
Permanently reduced (manual night mode)
For more information on the operating modes, refer to page 13.
If there is only one heating circuit installed and no DHW, heating circuit selection is not
possible.