49
Adjustment and commissioning
Notation convention:
.....
Green LED state
Red LED state
NO
YES
See general con-
guration dia-
gram, chapter9.3
Device in Read mode?
.....
To view time delay before switching
1 2 3 4 5 6 7 8 910
0 s
100 s
Bargraph shows current time delay before switching, 52s
in the example (by default = 100s)
Press push button four times briey
To set the factors of ten for the seconds of the time
delay before switching
Press and hold the push button
After 2 s, device is in Parameterizing mode:
A
Fig.43: Settingthetimedelaybeforerelayswitching,part1
If time delay before switching set to 52s,
LED no.6 ashes 9times then stays on
A
Next LEDs come on one after the other
B
Press and hold the push button
Release push button when LED has
ashed the desired number of times
After 2s, next LED ashes
1ash=1s
Release the push button when desired
number of LEDs is on.
1LED ON=10s
To set the seconds of the time delay before
switching
C D
Fig.44:
Settingthetimedelaybeforerelayswitching,part2