8
General information
4. GENERAL INFORMATION
4.1. Manufacturer's address and
international contacts
To contact the manufacturer of the device, use following
address:
Bürkert SAS
Rue du Giessen
BP 21
F-67220 TRIEMBACH-AU-VAL
You may also contact your local Bürkert sales oce.
The addresses of our international sales oces are available on
the internet at:
country.burkert.com.
4.2. Warranty conditions
The condition governing the legal warranty is the conforming use
of the device in observance of the operating conditions specied
in these Operating Instructions.
4.3. Information on the Internet
You can nd the Operating Instructions and technical data sheets
regarding the type8041 at: country.burkert.com.
5. DESCRIPTION
5.1. Area of application
The device is used to measure the ow of neutral or slightly
aggressive uids with a conductivity of more than 20µS/cm in
DN06 to DN400 pipes.
5.2. General description
5.2.1. Construction
The device comprises an electronic module and a PVDF or
stainless steel measurement sensor.
The ow sensor comprises two electrodes and a magnetic
system.
The connection of the device to the process is made depending
on the version, either by a G2" nut or a clamp.
Electrical connection is made via two cable glands on a 6-pin
terminal block.
The device requires an 18...36VDC power supply and has:
• a frequency output,
• a relay output,
• a 4...20mA current output.
english
Type 8041