Technical data
Identification on the device Certification Variable key
UL-recognized PU01
Measuring
Equipment
EXXXXXX
®
UL-listed PU02
6.1.3 Fluid data of a 8025 Batch in compact version
Type of fluid
neutral or slightly aggressive liquids
Fluid viscosity
max. 300 cSt
Rate of solid particles
max. 1%
Fluid temperature
The fluid temperature may be restricted by the fluid pressure
and the material the S020 fitting used is made of (see Fig. 8)
with S020 fitting in PVC 0...+50°C
with S020 fitting in PP 0...+80°C
with S020 fitting in PVDF, stainless steel or brass –15...+80°C
Fluid pressure
PN10 max
The fluid pressure may be restricted by the fluid
temperature and the material the S020 fitting used is made
(see Fig. 8)
Flow rate measurement
Measurement range 0,3...10 m/s
Measurement deviation
- with standard K-factor of the S020 fitting
- ±2.5% of the measured value
1)
- with K-factor determined with a Teach-In
procedure
- ±1% of the measured value
1)
(at the value of the
Teach-In flow rate)
Linearity ±0,5% of the full scale (10 m/s)
Repeatability ±0,4% of the measured value
1)
1)
Determined in the following reference conditions: medium = water, water and ambient temperatures 20 °C, min. upstream
and downstream distances respected, appropriate pipe dimensions
A
10
9
8
7
6
5
4
3
2
1
0
-15 0 +20 +40 +60
PVDF
PVDF (PN10)
PVC (PN10)
PP (PN10)
PVC + PP
11
P (bar)
T (°C)
+80
Metal
A: Operating range
Fig. 8 : Fluid temperature/pressure dependency curves for the 8025 Batch in compact version, depending on the material
the S020 fitting is made of