Operating and functions
If the generation of alarms (alarm "DURING") for problems occurring during a dosing has been activated
(see chap. 10.7.16), an alarm is generated if there is no flow rate measured in the pipe whereas the
valves are open. See chap. 11.3.4 to solve the problem.
If the generation of alarms (alarm "AFTER") for problems occurring at the end of the dosing has been
activated (see chap. 10.7.17), an alarm is generated if there is still flow in the pipe whereas the valves
are closed. See chap. 11.3.4 to solve the problem.
BAtCH M 0100.0L
OK Y/N
89.2 L
Enter a dosing quantity (value between 0.0001 and 99999 dosing units, where
the units have been selected in chap. 10.7.2) higher or equal to 6 divided by the
fitting K-factor (in pulse/litre).
Confirm.
Choose "OK Y" to start the dosing.
Confirm.
The dosing quantity is counted down until 0 (the dosing units blink).
To read the flow rate measured in the pipe, press
or
0......9
.
To read the total dosing quantity, press
or
0......9
once.
To interrupt the dosing, see Fig. 41.
Confirm.
Process level
0.1 L
When the dosing is finished:
the dosing units do not blink any more,
and the valves are closed.
To go back to the Process level in order to start a new dosing,
press
ENTER
.
Fig. 40 : Doing a manual dosing in dosing modes "LOC. MANU." or "MEM.+MANU."