UNIVERS
31
2023/03 - Revision index: A - Code: 0000139233
3C Advanced features
This sub-menu offers the possibility to change the settings for the
following 8 parameters:
3C1 Temperature Measurement
Selection:
Manual: the T°C value is imposed by the user and the
device no longer takes into account the probe reading.
The user must enter the value. Useful in case of T°C
probe failure and if the T°C is stable
Automatic: the device takes into account the value
indicated by the probe
3C2 Reed logic:
Used to define the idle state of the contact connected to a magnetic
flow sensor (connector 9)
Normally Closed (NC): closed without water circulation
Normally Open (NO): open without water flow
3C3 Pump Mode:
Defines the activation mode of the peristaltic pumps for product
injection, depending on the measured parameters.
For each of the parameters (pH, Redox, and possibly Free Chlorine),
the selections are :
1) OFF
2) Proportional (Prop.)
3) On-Off (all or nothing)
4) Timed (time-limited dosing, for small pools)
3C4 Wi-FI Info:
Displays information about the WiFi network to which the device is
connected:
- WiFi Alarm status
- SSID
- PSW
- IP address
3C5 Power ON delay:
This function allows the start of dosing to be delayed until the unit is
switched on, so that the probes have time to polarise correctly and
thus transmit reliable measurement values.
The delay before the start of dosing after switching on can be set
up to 90 minutes. The setting is made in minutes and seconds.
NB: If the setting is 0, there is no delay.
_3C__Advanced features____
1: Temp. Measure
2: Reed logic NC
3: Pump Mode
4: WiFi info
5: Delay P.ON OFF
6: Flow delay OFF
7: Pump circ. ON
8: Pool volume 130m³
01/07
_3C2____REED Logic_____
1: NC
2: NO
01/04
_3C1__Temp. measurement___
Temp Mode Manual
- Manual 25°C
01/02
_3C3__Pump mode_________
1: pH On-Off
2: Redox Timed
3: Chlorine Prop
01/03
_3C4__WiFi Info___________
1: WiFi Alarm Off
2: SSID KommSPOTvB73FCA
3: PSW 12345678
4: IP 192.168.3.1
01/03
_3C5____ P. delay ON________
00
m
01
s
_3C3___Type Dose__________
OFF
Prop
ON-OFF
Timed
01/03

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BWT Manager Connect Duo and is the answer not in the manual?

BWT Manager Connect Duo Specifications

General IconGeneral
BrandBWT
ModelManager Connect Duo
CategoryController
LanguageEnglish

Related product manuals