3C6 Delay Flow:
Similarly, this function allows the start of the actual dosing to be
postponed when the unit has been de-energised by the flow
controller due to insufficient water flow, and the correct flow rate has
been re-established, thus re-energising the unit.
The delay before the start of dosing after switching on can be set up
to 60 minutes. The setting is made in minutes and seconds.
NB: If the setting is 0, there is no delay.
3C7 Circulation pump:
This function enables (ON) or disables (OFF) the interlocking of the
power supply of the device with the power supply of the filter pump.
3C8 Pool volume:
This function is used to enter the volume of water in the pool system and for the device to set the
continuous dosing time in the "BOOSTER" function:
Setting to 0 disables the "BOOSTER" function
Note: do not forget to take into account the volume of the buffer tanks in the case of overflow tanks.
3D System Reset submenu
3D1 Reset Unit: resets all parameters to their value
factory
3E Firmware revision submenu
Displays the "Firmware" version