©2020 CAE 905K640152 v1.1 5
Cautions and Warnings
Potential Health Effects
Acute (short term): In the event that the cell or pack ruptures, the electrolyte solution
contained within the cell will corrode and can cause burns to skin and eyes.
Inhalation: Inhaling materials from a sealed cell is not an expected route of exposure.
Vapors or mists from a ruptured cell can cause respiratory irritation.
Ingestion: Swallowing materials from a sealed cell is not an expected route of exposure.
Swallowing the contents of an open cell can cause serious chemical burns to mouth,
esophagus, and gastrointestinal tract.
Skin: Contact between the cell and skin will not cause any harm. Skin contact with the
contents of an open cell can cause severe irritation or burns to the skin.
Eye: Contact between the cell and the eye will not cause any harm. Eye contact with the
contents of an open cell can cause severe irritation or burns to the eye.
Interactions with other chemicals: Immersion in high conductivity liquids can corrode
or breach the cell or battery enclosure. The electrolyte solution inside of the cells can react
with alkaline (basic) materials and present a flammability hazard.
First Aid Measures
The hazardous components of this cell or battery are contained within a sealed unit. The following
measures are only applicable if exposure has occurred to components when a cell or battery leaks, is
exposed to high temperatures or is mechanically, electrically or physically abused/damaged. The
hazardous contents are caustic alkaline electrolytes contained in cells with lithium metal oxide
cathodes, graphite and carbon anodes and polyvinyliden fluoride binders.
Ingestion: INDUCE VOMITING. Quickly transport victim to an emergency care facility.
Eye Contact: Do not rub eyes. Immediately flush the contaminated eye(s) with water for at
least 15 minutes. Quickly transport victim to an emergency care facility.
Skin Contact: Remove contaminated clothes and shoes immediately. Wash extraneous
matter or contact region with soap and plenty of water immediately. Seek medical
attention.
Inhalation: Make the victim blow his/her nose and gargle. Seek medical attention.
Fire Fighting Measures
In the event of a fire, suitable extinguishing media would be: plenty of water, carbon dioxide gas,
nitrogen gas, chemical powder fire extinguishing medium, and fire foam.
CAUTION: Corrosive gas may be emitted during the fire.
When the battery burns with other combustibles simultaneously, take a fire-extinguishing method
which correspond to the combustibles.