Using Ares
56 ©2020 CAE 905K640152 v1.1
CAEAres
Eyes
Each pupil of the Ares manikin can be set manually to a fixed diameter of 3.5 or 8 mm (normal or
blown) by carefully rotating the eye from left to right or right to left until the proper size appears.
Ares comes with:
• Normal pupils
• Blown pupils
• Closed eyelids
Matching Pupils
When physically moving the eyes, ensure that both eyes are rotated in the same direction, so the left
and right pupils appear to have the same focal point.
Temperature:
Body
Myocardial oxygen supply and
demand automatically influence the
cardiac rhythm, yielding response to
hypoxemia (Modeled only).
Tap Neuro and tap
Temperature: Body to
adjust.
None
required.
Temperature:
Blood
Changes in arterial temperature may
alter the position of the standard
oxyhemoglobin dissociation curve
(shift). As temperature increases or
pH decreases, more oxygen is
released from hemoglobin and thus
the patient’s saturation decreases
(Modeled only).
Tap Neuro and tap
Temperature: Blood
to adjust.
None
required.
Neurologic System Controls
Anatomy,
Physiology and
Clinical Signs
Clinical Interventions, Patient
Monitoring and Scenarios.
Software Control Manual
Control