Command and control devices
1
STOP button (NC contact)
Stop the gate and exclude automatic closing. Use a control device to resume movement.
When the contact is being used, it must be activated during programming.
2
Control device (NO contact)
OPEN ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during OPENING.
3
Control device (NO contact)
PARTIAL OPENING or PEDESTRIAN OPENING function
See [Adjusting partial opening] function.
4
Control device (NO contact)
CLOSE ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during CLOSING.
5
Control device (NO contact)
OPEN-CLOSE function
OPEN-STOP-CLOSE-STOP function
See control function 2-7.
6
Antenna with RG58 cable
1 2 3 3P 4 7
BUS