RIO ED T1
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
F65 RIO ED T1 OFF (Default)
P0 = It stops the gate and excludes automatic closing. Use
a control device to resume movement.
P7 = Reopen while closing.
P8 = Reclose while opening.
RIO ED T2
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
F66 RIO ED T2 OFF (Default)
P0 = It stops the gate and excludes automatic closing. Use
a control device to resume movement.
P7 = Reopen while closing.
P8 = Reclose while opening.
RIO PH T1
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
F67 RIO PH T1 OFF (Default)
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop. Only with [Automatic close] activated.
P4 = Obstacle standby.
P13 = Reopening during closure with immediate stop once
the obstacle has been removed, even with the gate not in
motion.
RIO PH T2
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
F68 RIO PH T2 OFF (Default)
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop. Only with [Automatic close] activated.
P4 = Obstacle standby.
P13 = Reopening during closure with immediate stop once
the obstacle has been removed, even with the gate not in
motion.