FINAL OPERATIONS
Securing the cover
Rest the cover on the foundation box, secure the hole cover and insert the cap on the cover.
UNI 5933 M6x12
Cover
Casing hole cover
Cap
MALFUNCTIONS POSSIBLE CAUSES CHECKS AND REMEDIES
The gate does not open or
close
• No power
• The gearmotor is unlocked
• The transmitter battery is flat
• The transmitter is broken
• The stop button is stuck or broken
• The opening/closing button or the key selector switch are stuck
• Check
for mains power
• Lock the gearmotor
• Replace the batteries
• Contact service
• Contact service
• Contact service
The gate opens but does not
close
• The photocells are engaged • Make sure that the photocells are
clean and work correctly
• Contact service
TROUBLESHOOTING