N.B.: An evaluation of the size of the cables with lengths other than the data in the table must be made based on the e ective
absorption of the connected devices, according to the instructions indicated by the CEI EN 60204-1 standards.
For connections that require several loads on the same line (sequential), the size given on the table must be re-evaluated based on
actual absorption and distances.
12 - Command divices (Keyboard, magnetic key, card, etc.)
13 - Column for reader
14 - Joint for rod
15 - Antenne
16 - Key-operated selector switch
5.3 Cable list and minimun thickness
Connections Type of cable
Length of cable
1 < 10 m
Length of cable
10 < 20 m
Length of cable
20 < 30 m
Alimentazione 230V
FROR CEI 20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 2,5 mm
2
3G x 4 mm
2
Photoelectric cells TX 2 x 0,5 mm
2
2 x 0.5 mm
2
2 x 0,5 mm
2
Photoelectric cells RX 4 x 0,5 mm
2
4 x 0,5 mm
2
4 x 0,5 mm
2
24V power supply accessory 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Safety and control divices 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
Antenna connection RG58 max. 10m
Metallic mass detector (see documents provided with product)
5.4 Standar installation
1 - GARD unit
2 - Control panel
3 - Aluminium bar
4 - Red phosphorescent strips
5 - Luminous cord
6 - Movement-indicating flashing lamp
7 - Column for photoelectric cells
8 - Photoelectric cells
9 - Fixed barrier support
10 - Magnetic sensor
11 - Photoelectric cell support

Other manuals for CAME GARD 8 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME GARD 8 SERIES and is the answer not in the manual?

CAME GARD 8 SERIES Specifications

General IconGeneral
ModelGARD 8 SERIES
TypeAutomatic Barrier
Motor voltage24 V DC
Power300 W
Operating temperature-20°C to +55°C
Protection ratingIP54
Input Voltage230 V AC
Output Voltage24 V DC
Protection DegreeIP54
Power supply230 V AC
Opening time4 to 8 seconds