INSTALLATION
Cable types and minimum thicknesses
Connection
cable length
< 20 m 20 < 30 m
Control panel 120 / 230 V AC (1P+N+PE) 3G x 1.5 mm
2
3G x 2.5 mm
2
Gearmotor 120 / 230 V AC 4G x 1.5 mm
2
4G x 2.5 mm
2
TX Photocells 2 x 0.5 mm
2
RX photocells 4 x 0.5 mm
2
Flashing light 2 x 0.5 mm
2
Command and control devices 2 x 0.5 mm
2
Safety devices 2 x 0.5 mm
2
When powered at 120 V or 230 V and used outdoors, use H05RN-F-type cables that comply with 60245 IEC 57 (IEC); whereas
indoors, use H05VV-F-type cables that are 60227 IEC 53 (IEC) compliant.
Use RG58 cable up to 10 m long to connect the antenna.
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of the
connected devices and according to the provisions of regulation CEI EN 60204-1.