FUNCTIONS AND SETTINGS
Perform all settings only when the shutter is not moving and completely stopped.
Functions DIP-SWITCH
AUTOMATIC CLOSING
Automatic closing active (1 OFF -
Deactivated)
OPEN-STOP-CLOSE-STOP
OPEN-STOP-CLOSE-STOP (sequential)
function from control device (NO contact)
and from radio transmitter fitted with AF
card.
OPEN-CLOSE-INVERT
OPEN-CLOSE-INVERT (step-step) function
from control device (NO contact) and from
radio transmitter fitted with AF card.
SAFETY TEST
At each open and close command, the
control board checks that the safety
systems are properly working (3 OFF -
Deactivated)
DELETING USERS
Deleting one or more users (4 OFF -
Deactivated)
Adjusting TRIMMER
OPERATING TIME
This sets the gearmotors' operating time. The operating
time can be adjusted to between 10 and 120 seconds.
Setting the time to its minimum engages the
maintained action function and disengages the
transmitters.
AUTOMATIC CLOSING TIME
For setting the shutter's waiting-time when up and open.
Once this time elapses, the shutter automatically closes.
The waiting time can be adjusted to between 1 and 120
seconds.
The automatic closing does not activate if the
safety devices are triggered due to obstacle detection,
after a total Stop or if the current is missing.