p. 12 - Manual FA00943-EN - 01/2018 - © CAME S.p.A. - Translation of the original instructions
Safety devices
Photocells
Input for safety devices such as photocells.
C1 REOPENING DURING CLOSING: when the shutter is closing, opening the contact triggers an inversion of movement, until it is
completely open again.
C7 REOPENING DURING CLOSING: when the shutter is opening, opening the contact triggers a quick inversion of movement, until
it is completely open again.
When the safety devices are not used, leave the safety test deactivated and bridge (2-C1)
and (2-C7).
When using only one photocell or a sensitive safety-edge with the safety test deactivated,
bridge - the unused one - with contact (2-C7).
When using only one photocell or a sensitive safety-edge with the safety test deactivated,
bridge - the unused one - with contact (C7-TS).