p. 16 - Manual FA00943-EN - 01/2018 - © CAME S.p.A. - Translation of the original instructions
Description of the warnings of the PRG button's LED.
- Quick fl ashing to warn that there is an obstruction in front of the photocells.
- Flashing every second for the entire automatic-closing time - if it is activated, that is, when there are obstructions in front of the
photocells during the automatic-closing time, the LED stays on steady until the obstruction is removed, after which, the count for
the automatic closing restarts from zero and the LED fl ashes.
- Quick fl ashing when attempting to save more than 50 users.
Preliminary operations
❶Connect the RG58 antenna-cable to the corresponding terminals.
❷Fit the AF card into the connector on the control board.
Before fi tting the AF card, you MUST CUT OFF THE MAINS POWER SUPPLY.
MANAGING USERS BY RADIO CONTROL