10.4.52 pppPassword
Specifies the password that will be used for PPP connections when the value of PPP Interface is
set to something other than Inactive.
l String data type
10.4.53 pppUsername
Specifies the user name that is used to log in to the PPP server.
l String data type
10.4.54 RouteFilters
This setting configures the data logger to restrict routing or processing of some PakBus message
types so that a "state changing" message can only be processed or forwarded by this data logger
if the source address of that message is in one of the source ranges and the destination address
of that message is in the corresponding destination range. If no ranges are specified (the
default), the data logger will not apply any routing restrictions. "State changing" message types
include set variable, table reset, file control send file, set settings, and revert settings.
If a message is encoded using PakBus encryption, the router will forward that message regardless
of its content. If, however, the routes filter setting is active in the destination node and the
unencrypted message is of a state changing type, the route filter will be applied by that end
node.
l String data type
10.4.55 RS232Handshaking
If non-zero, hardware handshaking is active on the RS-232 port. This setting specifies the
maximum packet size sent between checking for CTS.
10.4.56 RS232Power
Controls whether the RS-232 port will remain active even when communications are not taking
place. Note that if RS232Handshaking is enabled (handshaking buffer size is non-zero), that this
setting must be set to Yes.
l Boolean data type