RF Data Rate
l RF407, RF412, and RF427: 200 kbps
l RF422: 10 kbps
l RF451: 115.2 or 153.6 kbps
For RF additional current contribution specifications, see Power requirements (p. 211).
See also Radio communications option (p. 28).
11.9 Standards compliance specifications
View EU Declarations of Conformity at www.campbellsci.com/cr6.
Shock and Vibration:MIL-STD 810G methods 516.6 and 514.6
Protection: IP50
EMIand ESD protection:
l Immunity: Meets or exceeds following standards:
o
ESD: per IEC 61000-4-2; ±15 kV air, ±8 kV contact discharge
o
Radiated RF: per IEC 61000-4-3; 10 V/m, 80-1000 MHz
o
EFT: per IEC 61000-4-4; 4 kV power, 4 kV I/O
o
Surge: per IEC 61000-4-5; 4 kV power, 4kV I/O
o
Conducted RF: per IEC 61000-4-6; 10 V power, 10 V I/O
l Emissions and immunity performance criteria available on request.
RF407 Option
l United States FCC Part 15.247: MCQ-XB900HP
l Industry Canada (IC): 1846A-XB900HP
l Mexico IF: RCPDIXB15-0672-A1
RF412 Option
l ACMA RCM
l United States FCC Part 15.247:
l MCQ-XB900HP
l Industry Canada (IC): 1846A-XB900HP
RF422 Option: View EU Declaration of Conformity at www.campbellsci.com/cr6.
RF427 Option: Brazil ANATEL standards in Resolution No. 506: 08335-17-10644. View the RF427
Brazilian Certificate of Conformity at www.campbellsci.com/cr6.
11. CR6 Specifications 227