RG terminals can be configured to make analog current measurements using the CurrentSE
() instruction. When configured to measure current, terminals each have an internal resistance
of 101 in the current measurement loop. The return path of the sensor must be connected
directly to the G terminal closest to the terminal used. The following image shows a simplified
schematic of a current measurement.
6.2.1 Example Current-Loop Measurement Connections
The following table shows example schematics for connecting typical current sensors and
devices. See also Current-loop measurement specifications (p. 220).
6. Measurements 67