See also RF radio option specifications (p. 226).
3.1.5.2 RF407-Series radio communications with one or more data
loggers
To configure an RF407-series radio to communicate with the data logger, you must complete the
following steps (instruction follows):
l Ensure your data logger and RF407-series radio are connected to an antenna and power.
l Configure the connection to the RF407-series device using Device Configuration Utility.
l If you are connecting to multiple data loggers, you will have to assign unique PakBus
addresses to each data logger using Device Configuration Utility. (Connect to each data
logger, set the PakBus Address on the Deployment | Datalogger tab.)
l Use data logger support software to set up communications between the RF407-series
radio and the data loggers.
NOTE:
This procedure assumes the RF407 series devices are using factory default settings.
Configuring the RF407-Series radio
Configure the RF407-Series radio connected to the computer (see image in Configuration
options (p. 29) for reference).
3. Setting up the CR6 30