##280 TX Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##281 TX Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##282 TX Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##283 TX Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##284 TX After TCF transmission, DCN has been received.
##285 TX After EOP transmission, DCN has been received.
##286 TX After EOM transmission, DCN has been received.
##287 TX After MPS transmission, DCN has been received.
##288 TX After EOP transmission, a signal other than PIN, PIP, MCF, RTP, RTN has been received.
##289 TX After EOM transmission, a signal other than PIN, PIP, MCF, RTP, RTN has been received.
##290 TX After MPS transmission, a signal other than PIN, PIP, MCF, RTP, RTN has been received.
##670 TX In V.8 late start, the DIS V.8 ability from the receiving machine was detected, and CI was sent in
response; however, the procedure failed, causing T1 time-over.
##671 RX In V.8 call reception, the procedure fails to proceed to phase 2 after CM detection, causing T1 time-over.
##672 TX In V.34 transmission, the procedure fails to proceed from phase 2 to phase 3 or later, causing T1 time-
over
##673 RX In V.34 reception, the procedure fails to proceed from phase 2 to phase 3 or later, causing T1 time-over
##674 TX In V.34 transmission, the procedure fails to proceed from phase 3 or 4 to the control channel or later,
causing T1 time-over
##675 RX In V.34 reception, the procedure fails to proceed from phase 3 or 4 to the control channel or further,
causing T1 time-over
##750 TX After transmitting PPS-NULL in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##752 TX After transmitting PPS-NULL in ECM transmission, DCN has been received.
##753 TX After transmitting PPS-NULL in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##754 TX After transmitting PPS-NULL in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##755 TX After transmitting PPS-MPS in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##757 TX After transmitting PPS-MPS in ECM transmission, DCN has been received.
##758 TX After transmitting PPS-MPS in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##759 TX After transmitting PPS-MPS in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##760 TX After transmitting PPS-EOM in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##762 TX After transmitting PPS-EOM in ECM transmission, DCN has been received.
##763 TX After transmitting PPS-EOM in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##764 TX After transmitting PPS-EOM in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##765 TX After transmitting PPS-EOP in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##767 TX After transmitting PPS-EOP in ECM transmission, DCN has been received.
##768 TX After transmitting PPS-EOP in ECM transmission, re-transmission of the procedure signal has been