212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Page 82
Cont1= (Continuous Output Serial Port 1)
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys, 0/NO or 1/YES, enter the new
setting and then press the ENTER key to save it.
Cont1=YES
Cont1=NO
Continuous Output
No Continuous Output
If you selected Cont1=YES (Continuous Output), an additional
prompt, tyPE= will be displayed.
If you selected Cont1=NO (No Continuous Output) proceed to the
Weight On Demand section.
tyPE= (Continuous Output Format)
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys enter the new setting and then
press the ENTER key to save it. Allowable settings are 0, 1 or 2.
0 = SMA
1 = Cardinal Scoreboard
2 = SB-500
SMA Continuous Output Format
If SMA is selected, data will be transmitted in the following format:
<lf><s><r><n><m><f><xxxxxx.xxx><uuu><cr>
Where:
lf =
Line Feed
s =
Flags
Z= center of Zero, O = Overcap, E = zero
Error, e = weight not currently being displayed
r =
Range
1, 2, 3
n =
Mode
G = Gross, T = Tare, N = Net
m =
Motion
M = Motion, " "(blank) = no motion
f =
Custom
Custom flag
xxxxxx.xxx =
Weight
Six digits with decimal point
uuu =
Units
ton, lb, l/o, oz, t, kg, g
cr =
Carriage
Return
(hex 0D)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 212 Series and is the answer not in the manual?

Cardinal 212 Series Specifications

General IconGeneral
BrandCardinal
Model212 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals