212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Cont1= (Continuous Output Serial Port 1)
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys, 0/NO or 1/YES, enter the new
setting and then press the ENTER key to save it.
If you selected Cont1=YES (Continuous Output), an additional
prompt, tyPE= will be displayed.
If you selected Cont1=NO (No Continuous Output) proceed to the
Weight On Demand section.
tyPE= (Continuous Output Format)
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys enter the new setting and then
press the ENTER key to save it. Allowable settings are 0, 1 or 2.
SMA Continuous Output Format
If SMA is selected, data will be transmitted in the following format:
<lf><s><r><n><m><f><xxxxxx.xxx><uuu><cr>
Where:
Z= center of Zero, O = Overcap, E = zero
Error, e = weight not currently being displayed
G = Gross, T = Tare, N = Net
M = Motion, " "(blank) = no motion
Six digits with decimal point
ton, lb, l/o, oz, t, kg, g