212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Page 83
Cardinal Scoreboard Output Format
If Cardinal Scoreboard is selected, the data will be transmitted in the
following format:
<s><xxxxxx><d><uu><m><cc><cr>
Where:
s =
Sign
"-" = negative, " " (blank) = positive
xxxxxx =
Weight
Six digits
d =
Decimal point
Added to string if enabled in setup
uu =
Units
LB, OZ, KG, G
m =
Mode
G = Gross, N = Net
cc =
Weight Status
OC = overcap
CZ = center of zero
MO = motion
EE = weight not currently being displayed
cr =
Carriage Return
(hex 0D)
IMPORTANT! The RD2, RD3, SB250, and SB500 scoreboards
use the Cardinal Scoreboard format. When using the Traffic Light
feature of the SB500, use the SB500 format.
SB500 Output Format
This format should ONLY be used when using the Traffic Light feature of
the SB500 scoreboard.
Cont2= (Continuous Output Serial Port 2)
Press the ENTER key to show the current setting. If the setting displayed
is acceptable, press the ENTER key again to save it. Otherwise, using the
numeric keys, 0/NO or 1/YES, enter the new setting and then press the
ENTER key to save it.
Cont2=YES
Cont2=NO
Continuous Output
No Continuous Output
If Cont2=YES (Continuous Output) is selected, an additional prompt, tyPE=
will be displayed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 212 Series and is the answer not in the manual?

Cardinal 212 Series Specifications

General IconGeneral
BrandCardinal
Model212 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals