EasyManua.ls Logo

Cardinal 2240 - LOAD CELL TABLE

Cardinal 2240
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PARTS IDENTIFICATION
Item Part Number Description
1 See Table LOAD CELL W/CABLE ASSEMBLY
2 6013-0039 #6-32 HEX NUT
3 6013-0045 ¼ - 20 HEX NUT
4 6021-0654 #6-32 X .25 PAN HEAD MACHINE SCREW
5 6021-0665 #6-32 X .375 PAN HEAD MACHINE SCREW
6 6021-1020 #10-32 X .500 PAN HEAD MACHINE SCREW
7 6021-1197 #6-32 X .500 STAINLESS STEEL FILLISTER SCREW
8 6021-1401 ¼ - 20 X .500 ZINC PLATED SOCKET HEAD CAP SCREW
9 6021-2071 #6-32 X .250 STAINLESS STEEL FILLISTER SCREW
10 6021-6007 #6-32 X .250 PAN HEAD MACHINE SCREW
11 6024-0039 ¼ HELICAL LOCK WASHER
13 6540-1130 LEVELING FOOT
14 6610-2000 JACK SOCKET
15 6610-4019 1/4 ASB 3AG-1/4 ASB FUSE (2240)
15 6610-4012 1/8 ASB 3AG-1/8 ASB FUSE (2241)
16 6610-4046 FUSE HOLDER
19 6680-0004 #6 ZINC PLATED INTERNAL TOOTH LOCK WASHER
20 6680-0163 #6 X .375 SPACER
22 6680-1088 SELF CLINCHING LOW PROFILE PANEL FASTENER
23 6910-3026 BLACK SWITCH SNAP-IN FRAME
25 8526-B213-08 BATTERY DOOR
26 8526-B214-08 LOAD CELL SPACER
27 8526-B222-0A BATTERY POWER BOARD
28 8526-B232-08 BATTERY COVER SPRING (not shown)
29 8526-B233-08 INTERNAL SERIAL CABLE ASSEMBLY
30 8526-C206-08 WEIGHBRIDGE
31 8526-C207-08 COMMODITY TRAY
32 8526-C210-08 TOP BATTERY GUIDE
33 8526-C211-08 BASE PLATE
34 8526-C212-08 BOTTOM BATTERY GUIDE
35 8526-D201-0A CONTROLLER BOARD
36 8526-D203-08 DUST COVER
37 8526-D204-0A DISPLAY AND KEYPAD INTERFACE
38 8526-D205-08 BASE ENCLOSURE
39 8526-D209-0A FRONT PANEL
40 8526-D216-08 KEYPAD OVERLAY
41 8526-D217-0A ANALOG BOARD
42 8544-B032-0A LINE FILTER FILTER ASSEMBLY
6800-0018 BATTERY: CAM-350 TYPE 12 VOLT 2000 mAh (not shown)
LOAD CELL TABLE
Scale Capacity Load Cell Assembly
5 lb (2 kg) 2950-C114-1A
10 lb (5 kg) 2950-C114-1A
20 lb (10 kg) 2950-C116-2A
50 lb (20 kg) 2950-C119-1A
100 lb (50 kg) 2950-C120-4A
37
It should be noted that when replacing the
load cell, the four (4) bolts holding the
load cell to the scale base and the
weighbridge to the load cell must be
torqued to 80 in-lb +/- 5 in-lb.