24  Installation and Programming Guide 
Aritech Reliance XR Terminals 
 
 Top to bottom: 
•  Antenna 1 – after the board is installed in 
the metal enclosure, insert the antenna 
with the corresponding icon. 
•  Antenna 2 – after the board is installed in 
the metal enclosure, insert the antenna 
with the corresponding icon. 
•  LAN-, LAN+, NEG, POS – terminals for 
Aritech Reliance XR RS485 bus. 
•  S1 LEARN – enrollment button, hold 
down for 3s to activate automatic device 
enrollment feature. Hold down while 
powering up to reset the "installer" 
account to master installer user type with 
9713 PIN. 
•  TERM – term link for Aritech Reliance XR 
RS485 bus. A TERM link should be 
installed on the two furthest devices. 
•  AC, AC, EARTH – connect transformer 
(16VAC 1.5A) to terminals for power. 
•  OUTPUT 3- – open collector output 
switches to ground, follows “ready” state 
at default. 
•  - BLACK, + RED – connect leads to 12V 
Sealed Lead Acid backup battery. 
•  AUX+, BELL- – supervised output for 
connecting an external 12V siren or 
internal piezo screamer. 
•  OUTPUT 2- – open collector output 
switches to ground, follows “any alarm” 
action at default. 
•  OUTPUT 1- – open collector output 
switches to ground, follows “any siren” 
action at default. 
•  DATA, COM, POS – NetworX 3-wire bus 
for legacy modules and keypads. 
•  ZONE 1 to 4, COM – terminals to connect 
to zones. Supports single EOL, zone 
doubling, and dual EOL tamper 
monitoring. 
•  J14 – Ethernet WAN link header must be 
fitted if no communicator module is 
installed and must be removed to 
accommodate communicator module. 
•  Ethernet – connect Ethernet cable to 
RJ45 socket to provide internet 
connectivity to Aritech Reliance XR. 
•  J13 USBUP – 5-pin connector used to 
upgrade and program Aritech Reliance XR 
with USBUP tool. 
•  TAMPER – connect to panel box tamper. 
•  J11 – terminal to connect communicator 
module to Aritech Reliance XR.