54  Installation and Programming Guide 
6.  Trigger the keyfob learning function for 2 seconds (on 63-bit keyfobs hold down the arm 
and disarm buttons, on 80plus keyfobs hold down the Arm + 2 buttons). The screen will 
show the keyfob has been found and the Serial Number will appear. 
7.  The keyfob will have access to Area 1 and the panel will report the keyfob number to 
the Central Monitoring Station when it is used. 
8.  Click Save. 
Advanced Keyfob Programming 
Three levels of access are possible: 
1.  Area 1 only – this is the default behaviour after learning a keyfob. The User is set to 
“Use FOB Number as Standard User”. 
2.  All areas – Click the drop-down User menu to assign the keyfob a User number. The 
keyfob will inherit areas and permissions of that user. New users, the default Master 
user, and the default Standard user have access to ALL areas. The user number is 
reported to the Central Monitoring Station when the keyfob is used. 
3.  Custom permissions – Keyfobs can be restricted to selected areas.  
 
Simple Method: navigate to the User menu and select a suitable Area Group. The arm 
and disarm buttons on the keyfob will arm/disarm all areas in the Area Group. 
 
Advanced Method:  
a.  Create a new User. 
b.  Change the User Type to Custom. 
c.  Assign an unused Permission to the User. 
d.  Create one or more Area Groups. Each one has a set of selected areas. 
e.  Modify the Permission and assign the appropriate Area Group to the Control 
Groups displayed. For example, the Permission can Away Arm both Area 1 and 2 
but Disarm only Area 1. 
f.  Return to the Settings – Keyfob menu. 
g.  Select the User that has been created. 
The keyfob is now linked to the custom user, and the custom permissions will be 
applied. When the arm button is pressed, all areas in the Away Arm Control Group 
will be away armed. When the disarm button is pressed, all areas in the Disarm 
Control Group will be disarmed. 
Keyfob Options: 
•  Tick the Police option to allow Panic Alarms to be sent to the Central Monitoring Station 
when Arm + Disarm Buttons are pressed at the same time. In addition, the panel will 
display the status and sound audible alerts. Please consult with your Central Monitoring 