7-MAINTENANCE
Every100hours
Coolingpackage
WARNING
Chemicalhazard!
Followtheinstructionsonthecontainerwhenhandlinganti-freeze.
Failuretocomplycouldresultindeathorseriousinjury.
W1109A
1.Anadequatecapacityofradiator,hydraulicoilcooler
andchargeaircoolerisprovided.Thiscoolingpackage
ismountedonmachineframethroughisolatormounts.
PTIL14COM0059AA1
Batteryelectrolytelevel-Check
1.DANGER
Batterygascanexplode!
Topreventanexplosion:1.Alwaysdisconnect
thenegative(-)batterycablerst.2.Always
connectthenegative(-)batterycablelast.3.
Donotshortcircuitthebatterypostswithmetal
objects.4.Donotweld,grind,orsmokeneara
battery.
Failuretocomplywillresultindeathorserious
injury.
D0182A
Makesurethattheconnectingandcableterminals
arequiteclean,tightandcoatedwithpetroleumjelly.
Checktheelectrolytelevelinthecell.Itshouldbe10.0
15.0mm(0.40.6in)abovetheplates.Ifneces-
sary,topupusingdistilledwater.Checktheelectrolyte
levelmorefrequentlyinsummer.Makesurethatthe
connectingandcableterminalsarequiteclean,tight
andcoatedwithpetroleumjelly.
Checkthechargingconditionsofthebatteryusingan
acidhydrometer.Inwinter,itisessentialthatthebat-
terybewellcharged,astheelectrolyteinadischarged
batteryfreezesmoreeasilythaninabatterythatiswell
charged.
7-17

Table of Contents