6-MAINTENANCE
Inspectingtheelement
Checktheelementfordamagebyplacinganinspection
lightinsidetheelement.
NOTE:changetheelementiflightcanbeseenthrougha
hole,howeversmall.
SMIL16MEX0434AA7
6.Removethesecondaryelement(5).
NOTE:thesecondaryelement(5)cannotbecleanedand
mustbechanged.
SMIL16MEX1532AA8
7.Installthesecondaryelementandtheprimaryelement
intotheaircleaner.
8.Installthecover(1).
SMIL16MEX1530AA9
9.Lockthetwofastener(2).
NOTICE:theairowsensorisinstalledontheinletductof
theaircleaner.Payattentionnottoallowdusttoenterthe
inletductwhenreplacingtheaircleanerelement.
NOTE:if,aftercleaning,smokeexhaustisabnormal,be
suretoreplacetheprimaryelementoftheaircleaner.
SMIL16MEX1529AA10
6-42