SECTION 25 CONTROLLER FEATURES
25.4.18. Trigger Stop Distance
The distance the piston travels before stopping on a trigger input. This feature is
used to relieve the strain placed on the mechanical components by stopping the
gate smoothly when a trigger signal is received.
25.4.19. Beam Stop Distance
The distance the piston travels before stopping on a beam input. This value is
normally set to stop the gate as quickly as possible so as to prevent injury to
persons; it is recommended that the value be selected so as to prevent undue
stress on the installation.
25.4.20. Push Force Limit
Sets the maximum push force delivered by the operators. The maximum setting is
avalueof15andtheminimumisve.Thisisusefulincaseswherelimitedpush
force is required. This setting applies to both operators.
25.5. Menu 6 - IR beams
In a swing gate installation, in order to provide protection to a person or vehicle
moving through the entrance, it is necessary to have two sets of Safety Beams,
one across the driveway where the gates are closed and another where the gates
are open. Both sets of Safety Beams must be set as Closing Safety Beams,
preventing the gate from closing and stopping the gates if they have started to
close if the beams are obstructed.
However, across the line of the driveway up to where the gates open, it is also
recommended to have another set of Opening Safety Beams to prevent the
gate from opening if they are closed and stop if they are opening if the beams are
obstructed.
FIGURE 31
Outside Closing Beam
Gates will not close
IRBC
Transmitter
IRBC
IRBO Transmitter
IRBO
Inside Closing Beam
Gates will not close
Twoindependentnormally-closedinputsareprovidedforOpeningandClosing
Safety Beams.
IRBC
Transmitter
IRBO Transmitter