CONTROLLER FEATURES SECTION 25
25.4.11. Pre-open Delay
Allows a delay between a valid trigger signal being received and the gate
commencing movement in the opening direction. A Warning Light can be set to
activateduringthisdelay.(RefertoPre-ashModesofthefeature‘PillarLight’,
for more details.) This setting applies to both operators.
APre-openDelayistypicallyusedtoallowapedestriansucienttimetomove
clear of the gate area prior to the gate commencing movement, or for a warning
beacon to be activated.
25.4.12. Pre-close Delay
Allows a delay between a valid trigger signal being received and the gate
commencing movement in the closing direction. The delay will also occur if the
gate is set to close automatically. A Warning Light can be set to activate during
this delay.
APre-closeDelayistypicallyusedtoallowapedestriansucienttimetomove
clear of the gate area prior to the gate commencing movement, or for a warning
beacon to be activated.
(RefertoPre-ashModesofthefeature‘PillarLight’,formoredetails).
This setting applies to both operators.
25.4.13. Opening Speed
Sets the maximum piston opening speed in millimeters per second. This setting
applies to both operators.
25.4.14. Closing Speed
Sets the maximum piston closing speed in millimeters per second. This setting
applies to both operators.
25.4.15. Ramp-up Distance
SetstheRamp-upDistanceinmillimetersoftravelofthepistonwhenstarting.
Thisfeatureisusedtoallowforsmoothanduidgatemovementduringopening.
This setting applies to both operators
25.4.16. Ramp-down Distance
SetstheRamp-downDistanceinmillimetersoftravelofthepistonwhenstopping.
This setting applies to both operators. This feature is used to allow for a smooth
deceleration of the gate to prevent the gate from stopping abruptly and placing
undue stress on the installation.
25.4.17. Crawl Distance
SetsthenalCrawlDistanceinmillimetersoftravelofthepistonwhenreaching
an endpoint. This setting applies to both operators.