page 44 www.CentSys.com
25.4.4. Short Stop value
The Short Stop distance can be set between 1mm and 20mm of piston stroke.
25.4.5. PCM push force
The amount of force applied by the operator when in PCM can be set as a value
from33%to100%inveincrements.
25.4.6. Positive Open Mode (POM)
Setting Positive Open Mode to ON will allow the gate to drive up hard to the open
endstop without causing the collision circuitry to operate. This feature operates
only during the last few millimetres of gate travel in Opening Mode.
25.4.7. Positive Open type
POM can be applied to one of the following:
• MasterMotor(MTRM)
• SlaveMotor(MTRS)
• Both Master and Slave Operators
25.4.8. POM Push Force
The amount of force applied by the operator when in POM can be set as a value
from33%to100%inveincrements.
25.4.9. Leaf Delay
Leaf Delay is used in cases where one gate leaf must move before the other.
Themostcommonneedforthisariseswhenamechanical‘lip’isttedtooneof
the gates.
In a double leaf installation, a Leaf Delay can be set whereby the
MTRSMotorwillclosebeforetheMTRMMotor.
SECTION 25 CONTROLLER FEATURES
25.4.10. Leaf Delay
value
The Leaf Delay is based on
piston position, and can be
adjusted from 1mm to 250mm
of piston travel.
FIGURE 30
Mechanical lip on Slave gate
engages with Master gate
Leaf Delay
Master gate will start to
move after Leaf Delay