4.1.6. PIRAC Mode (Beam Autoclose Mode) - Optional
This mode can only be used if a Closing Safety Beam is tted.
This mode can be used in
conjunction with any of the
operating modes - Standard,
Condominium and Reversing Mode.
With PIRAC Mode enabled, your gate
will close as soon as you have driven
through and passed the Closing
Safety Beam – giving intruders no
time to follow behind you.
If Autoclose is enabled and the
gate has been opened but nothing
moves through the Closing Safety
Beam, the gate will stay fully open
for the duration of the Autoclose
timer before closing. However,
if something passes through the
Closing Safety Beam the gate will
close immediately.
If something crosses the beam
while the gate is opening, it will
continue to open until the beam
is cleared and the gate will then
stop and close. If the gate has
reached its fully open position, it
would stop and remain open
until the beam is cleared.
PIRAC mode’s ‘stop on opening’
conguration will open the gate
a short, adjustable distance past
the point at which the beam was
broken and stop, wait for the
beam to be re-made or the
Autoclose timer to expire, then
close.
FEATURES AND FUNCTIONS SECTION 4
Beam
Beam broken
Beam re-made
Gate opening
Gate opening
Gate
closing