4.1.8. Positive Close Mode
Positive Close Mode is intended for applications where the gate must close fully against
the gate end post for security reasons – such as ensuring proper contact of the switch on
the gate that feeds power to the electric fence.
This feature operates only during the last few millimetres when the gate closes.
It is recommended that a rubber strip be xed to the front edge of the gate to
cut down the noise when the gate closes against the end post.
4.1.9. Operator Run Proles
The D5-Evo DOMESTIC, D10 and the D10 Turbo can be customised to your
exact requirements using your LCD controller. The open and closing speeds can be
independently set. Even the ramp up to full speed, ramp down to close speed and crawl
distance before the gate stops can be adjusted. Please contact Centurion Systems (Pty)
Ltd for more information on nding the conguration that is best for you.
FEATURES AND FUNCTIONS SECTION 4
4.1.7.1 Emergency Stop
The Holiday Lockout function can
also be used as an Emergency Stop
function. Mount an emergency stop
pushbutton in a weatherproof
housing near the gate and you can
bring your gate to an immediate
stop with just one press. The
emergency stop button must
be reset before the gate can be
operated again.
FIGURE 21
Emergency Stop will override normal Holiday Lockout Mode functions
If somebody tries to open the gate via a valid access control device, such
as a remote control, etc. with Holiday Lockout Mode enabled, the onboard
buzzer will beep periodically for 30 seconds to conrm that the gate
operation has been disabled using this feature.
The emergency stop is typically used at a manned entrance so that security
is not compromised with a would-be intruder possibly gaining access to
the stop button. In a domestic situation you can set up one of your remote
pushbuttons to operate the emergency stop without compromising your
security