Condensing Pool Heater Genie S
17
User Setup Mode
Switch on with the panel switch whilst pressing the Lock/Reset button. then release. The control is now in
Setup Mode.
The control can now be altered by rotating the Pool Temperature Control Knob to a certain position and then
pressing the Lock/Reset button, then switching off . (See Fig. 9.0)
Example:
To change from Fahrenheit to Centigrade:
Turn Panel Switch OFF then back ON whilst pressing the Lock/Reset button.
Turn the Pool Temperature Control Knob until the display shows ‘F’.
Press the Lock/Reset button once and the display will show ‘C’.
Switch the Panel Switch OFF then back ON again.
The Control will now display in Centigrade.
Lock/Reset
Button
On / Off
Switch
Temperature
Display
Pool Temperature
Control Knob
Fig. 9.0
User Setup Mode Setting Factory Setting Alternative Display Indicator
1 Display units ° F = Fahrenheit ° C = Centigrade ° F or ° C
2 Maximum temperature 32 °C (90 °F) 41 °C ( 106 °F) PL or SPA
3 Software Version e.g 020