CESSNA SECTION 3
MODEL T182T NAV III EMERGENCY PROCEDURES
GFC 700 AFCS
U.S.
FIRES (Continued)
ENGINE FIRE IN FLIGHT
1. Mixture Control - IDLE CUTOFF (pull full out)
2. FUEL SELECTOR Valve - PUSH DOWN and ROTATE to OFF
3. FUEL PUMP Switch - OFF
4. MASTER Switch (ALT and BAT) - OFF
5. Cabin Vents - OPEN (as needed)
6. CABIN HT and CABIN AIR Control Knobs - OFF (push full in)
7. Airspeed - 100 KIAS (If fire is not extinguished, increase glide
speed to find an airspeed, within airspeed limitations, which will
provide an incombustible mixture)
8. Forced Landing - EXECUTE (refer to EMERGENCY LANDING
WITHOUT ENGINE POWER)
ELECTRICAL FIRE IN FLIGHT
1. STBY BATT Switch - OFF
2. MASTER Switch (ALT and BAT) - OFF
3. Cabin Vents - CLOSED (to avoid drafts)
4. CABIN HT and CABIN AIR Control Knobs - OFF (push full
in) (to avoid drafts)
5. Fire Extinguisher - ACTIVATE (if available)
6. AVIONICS Switch (BUS 1 and BUS 2) - OFF
7. All Other Switches (except MAGNETOS switch) - OFF
WARNING
AFTER THE FIRE EXTINGUISHER HAS BEEN USED,
MAKE SURE THAT THE FIRE IS EXTINGUISHED
BEFORE EXTERIOR AIR IS USED TO REMOVE SMOKE
FROM THE CABIN.
8. Cabin Vents - OPEN (when sure that fire is completely
extinguished)
9. CABIN HT and CABIN AIR Control Knobs - ON (pull full out)
(when sure that fire is completely extinguished)
(Continued Next Page)
T182TPHBUS-01
3-11

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cessna skylance tc T182T and is the answer not in the manual?

Cessna skylance tc T182T Specifications

General IconGeneral
BrandCessna
Modelskylance tc T182T
CategoryToy
LanguageEnglish

Related product manuals