SECTION 3 CESSNA
EMERGENCY PROCEDURES MODEL T182T NAV III
GFC 700 AFCS
U.S.
ELECTRICAL POWER SUPPLY SYSTEM MALFUNCTIONS
(Continued)
IF LOW VOLTS ANNUNCIATOR REMAINS ON (Continued)
NOTE
The Main Battery supplies electrical power to the Main
and Essential Buses until M BUS VOLTS decreases
below 20 volts. When M BUS VOLTS falls below 20
volts, the Standby Battery System will automatically
supply electrical power to the Essential Bus for at least
30 minutes.
Select COM1 MIC and NAV1 on the audio panel and
tune to the active frequency before setting AVIONICS
BUS 2 to OFF. If COM2 MIC and NAV2 are selected
when AVIONICS BUS 2 is set to OFF, the COM and NAV
radios cannot be tuned.
j. COM1 and NAV1 - TUNE TO ACTIVE FREQUENCY
k. COM1 MIC and NAV1 - SELECT (COM2 MIC and NAV2 will
be inoperative once AVIONICS BUS 2 is selected to OFF)
NOTE
When AVIONICS BUS 2 is set to OFF, the following items
will not operate:
l. AVIONICS Switch (BUS 2) - OFF (KEEP ON if in clouds)
9. Land as soon as practical.
NOTE
Make sure a successful landing is possible before
extending flaps. The flap motor is a large electrical load
during operation.
Autopilot Audio Panel
COMM 2 NAV 2
Transponder MFD
T182TPHBUS-00
3-20

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cessna skylance tc T182T and is the answer not in the manual?

Cessna skylance tc T182T Specifications

General IconGeneral
BrandCessna
Modelskylance tc T182T
CategoryToy
LanguageEnglish

Related product manuals