Page #21 background imageLoading...
Page #21 background image
20
N.O.
COM
N.C.
N.O.
COM
N.C.
+
+
+
+
+
+
+
SHADOW INTERUPT EXIT
SBC
OPN
CLS
STP
COM
EYE
ONLY
EYE/
EDGE
EYE/
EDGE
COM
1
2
3
OPEN
CLOSE
TO MAIN
BOARD
POWER
N.C.
N.O.
COM
+
+
+
+
+
+
+
+
+
+
COMM
LINK
BA
BIPART
DELAY
2
4
6
8
HANDING
OPEN
LEFT
OPEN
RIGHT
ANTENNA
CURRENT
SENSOR
MOTOR DRIVE
RPM & LIMITS
ALARM
EXP.
BOARD
24 VAC IN
CLASS 2 SUPPLY
24 VAC
500 mA MAX
ID RESET
GND
Maglock
(Optional)
Solenoid Lock
(Optional)
OR
Shielded Twisted Pair Cable (Primary/Secondary
link to other gate operator) Ground the shield of the
cable to the chassis ground of each operator.
ACCESSORY
POWER
24 Vac 500 mA
Maximum
(Not Provided)
(Not Provided)
N.C.
INTERRUPT LOOP or
PHOTOELECTRIC SENSORS for CLOSE cycle
EDGE SENSOR for CLOSE cycle
EDGE SENSOR or
PHOTOELECTRIC SENSORS
for OPEN cycle
SHADOW LOOP
EXIT LOOP
FIRE DEPARTMENT
3-BUTTON
CONTROL
STATION
CONTROL BOARD
HEATER
SHADOW LOOP
EXIT LOOP
INTERRUPT
LOOP
AUXILIARY
RELAY 2
AUXILIARY
RELAY 1
SINGLE BUTTON
CONTROL STATION
3-BUTTON
CONTROL STATION
PHOTOELECTRIC SENSORS
PHOTOELECTRIC SENSORS or
EDGE SENSORS
NOTE: These switches determine if the
corresponding photoelectric sensor or edge
sensor will function for the OPEN or CLOSE cycle.
PLUG-IN LOOP DETECTOR
Model LOOPDETLM
NOTE: These switches control how
the Auxiliary Relays will function.
EXPANSION BOARD
JUNCTION BOX
L
N
GND
Incoming Power
N.C.
To protect against fire and electrocution:
DISCONNECT power BEFORE installing or servicing operator.
For continued protection against fire:
Replace ONLY with fuse of same type and rating.
WIRING
FIELD WIRING
This manual downloaded from http://www.manualowl.com

Table of Contents

Other manuals for Chamberlain ELITE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chamberlain ELITE Series and is the answer not in the manual?

Chamberlain ELITE Series Specifications

General IconGeneral
Battery BackupYes
Motor TypeDC
Power Supply120V AC
Remote ControlYes
Max Gate Length20 feet
Smart Home CompatibilityYes (MyQ compatible)
Maximum Gate Width20 feet