24
Inside
Property
Outside
Property
Entrapment Danger
Outside
Property
Inside
Property
Inside Property
Outside Property
Entrapment Danger
Safety Danger
Strike Open
Push Button
Strike Open
Push Button
24 Volts DC24 Volts DC
Fire Dept
Key Switch
Fire Dept
Key Switch
M/S LinkM/S Link
Class 2
Supply
Class 2
Supply
Center
Loop
Center
Loop
Safety
Loop
Safety
Loop
Radio
Receiver
Radio
Receiver
Exit
Loop
Exit
Loop
GG BB AA
ññ
++
OmniControl Surge Suppressor
P/N Q410
Patent Pending
P/N Q410
Patent Pending
®
7 121098
1 65432
G AB
1311
Strike Open
Push Button
Strike Open
Push Button
24 Volts DC24 Volts DC
Fire Dept
Key Switch
Fire Dept
Key Switch
M/S LinkM/S Link
Class 2
Supply
Class 2
Supply
Center
Loop
Center
Loop
Safety
Loop
Safety
Loop
Radio
Receiver
Radio
Receiver
Exit
Loop
Exit
Loop
GG
BB AA
ññ
++
OmniControl Surge Suppressor
P/N Q410
Patent Pending
P/N Q410
Patent Pending
®
7 121098
1 652
G AB
43
11 13
CENTER SAFETY EXIT
CENTER SAFETY EXIT
FIRE
DEPT.
STRIKE
OPEN
RADIO
RECEIVER
TIMER
SYSTEM ON
EXIT
LOOP
ALARM
SENSOR
REVERSE
SENSOR
OPEN
STOPCLOSE
SAFETY
LOOP
CENTER
LOOP
GATE
LOCKED
60
POWER
OVERLOAD
OFF
W4
OPEN LEFT
DC-BACKUP
ALARMSENSOR
OPEN RIGHT
3
SENSORS
RESET
MOTOR
COMMAND
PROCESSED
ON
G B
MS LINK
A
MADE IN USA
UP
ALARMSENSOR
ENTRAPMENT PROTECTION DEVICES
Non-Contact Sensors (12Vdc Photoelectric Sensors)
Contact your local dealer for more
information about photoelectric sensors.
To prevent SERIOUS INJURY or DEATH from a moving gate:
Locate entrapment protection devices to protect in BOTH the
open and close gate cycles.
Locate entrapment protection devices to protect between
moving gate and RIGID objects, such as posts or walls.
WARNING
WARNING
CAUTION
ENGLISH
SPANISH
ADVERTENCIA
ADVERTENCIA
PRECAUCIÓN
ADVERTENCIA
WARNING
Gate in Open Position
NOTE: Property owners are obligated to test photoelectric sensors monthly.
NOTE: If the photoelectric beam gets blocked
while the gate is closing, it will stop and
reopen. The gate will remain open until the
obstruction is cleared.
Safety Non-Contact Sensor
Entrapment Non-Contact Sensor
It is best to use Failsafe Photoelectric Sensors for this Safety Option.
Failsafe Photoelectric Sensors: If a failsafe photoelectric sensor is not working or
loses power or photoelectric beam is blocked, then the photo beam will stop ALL
gate operation.